Manual Transfer Switch Installation in Nashville & Middle Tennessee

Connect Your Portable Backup Power to Your Home — Safely.

Evolution Electric and Generators of Nashville provide professional manual transfer switch installation for homeowners who want to power essential household circuits during an outage using a compatible portable generator or battery power station.

Our licensed electricians evaluate equipment compatibility, install approved transfer equipment, connect selected circuits, and test the completed installation.

(615) 961-5930
Generac-Trained Installation Professional
Generac Dealer
IBEW Journeyman Electrician
Licensed Electrical Contractor
Residential electrical panel with circuit breakers prepared for professional electrical work
01 / Installation options

Two ways to get your transfer switch installed.

Option A

Evolution Electric-Supplied Manual Transfer Switch

Starting at$1,999installed

for qualifying standard installations.

Includes
  • Evolution Electric-supplied Reliance manual transfer switch.
  • Standard wiring, fittings, connectors, and mounting materials.
  • Professional installation by licensed electricians.
  • Connection of approved, compatible household circuits.
  • Circuit identification and labeling.
  • Applicable installation and operational testing.
  • Basic homeowner operating instructions.

Price is subject to site conditions, selected switch model, electrical compatibility, scope, and any required permits or additional work.

The generator or portable battery power station is not included.

Request an Installation Estimate
Option B

Customer-Supplied Manual Transfer Switch

Custom installation pricing

Based on equipment compatibility, electrical panel configuration, number of circuits, wiring requirements, and site conditions.

All customer-supplied equipment must be approved for the proposed installation. We review the make, model and specifications before quoting.

Portable generators and battery power stations are sold separately unless expressly included in your written proposal.

Request a Custom Quote
02 / Equipment compatibility

Compatible Portable Generators & Battery Backup Systems

We regularly evaluate equipment from these categories and brands for transfer switch connection. Listing a brand here does not mean every model is compatible.

Jackery
Select power stations and home backup models
Anker SOLIX
Select portable power stations
EcoFlow
Select DELTA-series power stations
BLUETTI
Select power stations
Portable generators
Compatible gasoline, propane and dual-fuel models

Compatibility is verified model by model.

Whether your equipment can be connected depends on:

  • Specific make and model
  • Rated running and surge output
  • Voltage (120V or 120/240V)
  • Neutral and grounding configuration
  • Connection method and inlet type
  • Transfer switch specifications
  • Manufacturer instructions

Brand names are trademarks of their respective owners. Listing a brand here does not indicate a manufacturer partnership, authorization or endorsement for transfer switch installation.

Portable gasoline generator on open pavementPortable battery power station with a folding solar panel outdoors
03 / How it works

How a manual transfer switch works.

  1. 01

    Connect

    The homeowner connects an approved backup power source using the correct equipment and connection method, such as a properly rated inlet and cord.

  2. 02

    Transfer

    The homeowner manually transfers selected circuits from utility power to backup power at the transfer switch.

  3. 03

    Power selected loads

    The connected source supplies only the circuits and loads within its approved capacity. Loads beyond that capacity must stay off.

  4. 04

    Transfer back

    When utility service returns, the homeowner follows the manufacturer's approved procedure to transfer back to utility power.

Never backfeed a home through an ordinary receptacle or use improvised generator connections.

So-called "suicide cords" and other improvised connections can send power back onto utility lines, endangering line workers and neighbors, and can cause fires, equipment damage and electrocution. An approved transfer switch isolates your selected circuits from the utility before backup power is connected.

04 / Manual vs automatic

Manual transfer switch vs automatic standby system.

Manual transfer switch

  • • You connect the power source and switch circuits yourself
  • • Powers a limited set of selected circuits
  • • Uses a portable generator or battery power station you own or buy
  • • Lower upfront cost; runtime depends on fuel or battery capacity

Automatic standby generator

  • • Starts and transfers automatically during an outage
  • • Can be sized for most or all of the home
  • • Permanently installed, fueled by natural gas or propane
  • • Higher investment; hands-free operation
See standby generator installation

Prefer to use your existing panel? Generator inlet & interlock installation →

Portable generators vs home battery systems

Portable fuel generators can run as long as you refuel them, but must operate outdoors, away from doors, windows and vents, because of carbon monoxide. Battery power stations are quiet and fume-free, but runtime is limited by stored capacity unless they are recharged. Permanently installed home batteries add automatic switchover and larger capacity.

Compatibility and load limitations

A transfer switch does not increase what your equipment can deliver. The circuits you choose, and what you run on them at the same time, must stay within your generator or power station's rated output. Large loads such as central air, electric ranges, electric dryers and water heaters often exceed portable equipment capacity. We do not promise runtime or whole-home coverage without an electrical assessment.

05 / Why professional installation matters

Done right the first time.

Code-compliant, isolated connection

Approved transfer equipment keeps backup power separated from utility lines.

Right circuits, clearly labeled

We identify and label each backed-up circuit so you know exactly what is powered.

Equipment checked first

We confirm your generator or power station is suitable before connecting it.

Tested before we leave

Applicable installation and operational testing, plus a walkthrough of the operating steps.

Circuits homeowners often choose

  • Refrigerator and freezer
  • Selected lighting circuits
  • Furnace blower or gas furnace controls
  • Wi-Fi, modem and selected receptacles
  • Sump pump (where capacity allows)
  • Medical devices (consult your provider)

Final circuit selection depends on your equipment's capacity and an electrical assessment.

Our installation process

  1. Assessment

    We review your panel, equipment make and model, and the circuits you want backed up.

  2. Written proposal

    Itemized scope and price. It states whether permit fees are included or billed separately.

  3. Installation

    Licensed electricians install the transfer switch and approved connection equipment, and handle applicable permits and inspections.

  4. Testing & walkthrough

    Operational testing and basic homeowner operating instructions.

06 / Pricing

What affects your final cost.

Standard installation packages start at $1,999 for qualifying installations using an Evolution Electric-supplied Reliance manual transfer switch. Customer-supplied equipment is quoted individually.

  • Transfer switch model and number of circuits
  • Distance between the panel, switch and power inlet
  • Panel condition, space and configuration
  • Equipment compatibility and connection hardware
  • Permit and inspection requirements
  • Any additional electrical work found during assessment

Permits: Evolution Electric handles applicable electrical permits and coordinates required inspections where necessary. Your written proposal states whether permit fees are included or billed separately. Generators and battery power stations are sold separately unless expressly included. Financing options →

FAQ

Common questions.

Can I connect a Jackery or Anker battery to my home?+

Possibly. Some Jackery, Anker SOLIX, EcoFlow and BLUETTI power stations are designed to connect to a transfer switch, while others are not. It depends on the specific model's rated output, voltage (120V vs 120/240V), neutral and grounding configuration, available output connection, and the manufacturer's instructions. We verify your exact model before recommending or installing anything.

Can a manual transfer switch run my air conditioner?+

Only if your backup source can safely supply the air conditioner's starting and running load and the circuit is approved for connection. Most portable generators and power stations cannot run central air. Many homeowners prioritize refrigeration, lighting, furnace blower, Wi-Fi and medical devices instead. We review your equipment and loads during the assessment.

Do I need a permit?+

In many Middle Tennessee jurisdictions, yes. Evolution Electric handles applicable electrical permits and coordinates required inspections where they are necessary. Your written proposal states whether permit fees are included in your price or billed separately.

Will the system switch over automatically?+

No. A manual transfer switch requires you to connect the backup power source and move the selected circuits to backup power yourself, following the manufacturer's procedure. If you want hands-free automatic switchover, an automatic standby generator or a home battery system with automatic transfer is the better fit.

Can I use an existing portable generator?+

Often, yes, if it is in good working order and its output, voltage, receptacle type and grounding configuration are compatible with the transfer switch and inlet. We confirm compatibility before installation. We will not connect equipment we cannot verify is suitable.

How many circuits can I back up?+

It depends on the transfer switch model you choose and, more importantly, the capacity of your generator or power station. Manual transfer switches are commonly offered in configurations covering a limited number of selected circuits. We help you choose the circuits that matter most within your equipment's approved capacity.

Does the $1,999 package include a generator?+

No. The package starting at $1,999 covers an Evolution Electric-supplied Reliance manual transfer switch and the standard installation scope listed on this page for qualifying installations. Portable generators and battery power stations are sold separately unless expressly included in your written proposal.

Can you install a transfer switch I already bought?+

Yes, when the equipment is approved for the proposed installation. Customer-supplied transfer switch installations are priced individually based on compatibility, panel configuration, number of circuits, wiring requirements and site conditions.

Ready when you are

Find out if a transfer switch fits your home
in about 60 seconds.

Answer a few quick questions and we'll follow up with a right-sized plan — or an alternative platform if it turns out to be a better fit for your home.